Wednesday, August 1, 2012

Autosys Can Only Run 10 Jobs

On Autosys Server:
# inetadm -p
NAME=VALUE
bind_addr=""
bind_fail_max=-1
bind_fail_interval=-1
max_con_rate=-1
max_copies=-1
con_rate_offline=-1
failrate_cnt=40
failrate_interval=60
inherit_env=TRUE
tcp_trace=TRUE
tcp_wrappers=TRUE
connection_backlog=10
# inetadm -l svc:/network/auto_remote/tcp:default
SCOPE    NAME=VALUE
         name="auto_remote"
         endpoint_type="stream"
         proto="tcp"
         isrpc=FALSE
         wait=FALSE
         exec="/opt/CA/autosys/bin/auto_remote"
         user="root"
default  bind_addr=""
default  bind_fail_max=-1
default  bind_fail_interval=-1
default  max_con_rate=-1
default  max_copies=-1
default  con_rate_offline=-1
default  failrate_cnt=40
default  failrate_interval=60
default  inherit_env=TRUE
default  tcp_trace=TRUE
default  tcp_wrappers=TRUE
default  connection_backlog=10

Solution:
inetadm -M connection_backlog=30